Wiring Instructions for the new 5002E Series VCB-1 Board

CONNECTOR  P1

Pin 1       GND

Pin 2       +12VDC

Pin 4       Bill Acceptor pulse

Pin 5       Push Button pulse

Pin 6       Empty RED LED.       NOTE: must run a wire from (P3, Pin 2) to P1, Pin 6.  When Empty Switch grounds, the Red LED comes ON.

Pin 7       LED power +12VDC through a 1K resistor

Pin 8       6 digit Mechanical Meter (+12VDC) using Pin 9 w/o diode

Pin 9       +12VDC w/o 1K resistor

Pin 10     Ready LED (Green) side of BI-color

INFORMATION NOTES:

 If any one of the four following conditions occurs, the Green LED will be turned OFF.

1.                    Empty Sensor

2.                    Busy (in dispense cycle)

3.                    Sensor 2

4.                    Jammed

The Red LED is turned ON when the Empty Sensor Switch indicates empty.  The LED can flicker if the switch is bouncing.

The card is always HELD.

The # retries for a jam is set to 7.

DIP SWITCHES:

A VERSION DIP SWITCHES:

sw 1 - 4 "off" = $0
sw 1 "on" = $1
sw 2 "on" = $2
sw 3 "on" = $4
sw 4 "on" = $8

 

B VERSION DIP SWITCHES:

sw 1 - 4 "off" = $0
sw 1 "on" = $1
sw 2 "on" = $5
sw 3 "on" = $10
sw 4 "on" = $20

 

C VERSION DIP SWITCHES:

sw 1 - 4 "off" = $0
sw 1 "on" = $5
sw 2 "on" = $10
sw 3 "on" = $20
sw 4 "on" = $40

 

The version number firmware is: A or B or C

[ END OF DOCUMENT ]